| 1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495969798991001011021031041051061071081091101111121131141151161171181191201211221231241251261271281291301311321331341351361371381391401411421431441451461471481491501511521531541551561571581591601611621631641651661671681691701711721731741751761771781791801811821831841851861871881891901911921931941951961971981992002012022032042052062072082092102112122132142152162172182192202212222232242252262272282292302312322332342352362372382392402412422432442452462472482492502512522532542552562572582592602612622632642652662672682692702712722732742752762772782792802812822832842852862872882892902912922932942952962972982993003013023033043053063073083093103113123133143153163173183193203213223233243253263273283293303313323333343353363373383393403413423433443453463473483493503513523533543553563573583593603613623633643653663673683693703713723733743753763773783793803813823833843853863873883893903913923933943953963973983994004014024034044054064074084094104114124134144154164174184194204214224234244254264274284294304314324334344354364374384394404414424434444454464474484494504514524534544554564574584594604614624634644654664674684694704714724734744754764774784794804814824834844854864874884894904914924934944954964974984995005015025035045055065075085095105115125135145155165175185195205215225235245255265275285295305315325335345355365375385395405415425435445455465475485495505515525535545555565575585595605615625635645655665675685695705715725735745755765775785795805815825835845855865875885895905915925935945955965975985996006016026036046056066076086096106116126136146156166176186196206216226236246256266276286296306316326336346356366376386396406416426436446456466476486496506516526536546556566576586596606616626636646656666676686696706716726736746756766776786796806816826836846856866876886896906916926936946956966976986997007017027037047057067077087097107117127137147157167177187197207217227237247257267277287297307317327337347357367377387397407417427437447457467477487497507517527537547557567577587597607617627637647657667677687697707717727737747757767777787797807817827837847857867877887897907917927937947957967977987998008018028038048058068078088098108118128138148158168178188198208218228238248258268278288298308318328338348358368378388398408418428438448458468478488498508518528538548558568578588598608618628638648658668678688698708718728738748758768778788798808818828838848858868878888898908918928938948958968978988999009019029039049059069079089099109119129139149159169179189199209219229239249259269279289299309319329339349359369379389399409419429439449459469479489499509519529539549559569579589599609619629639649659669679689699709719729739749759769779789799809819829839849859869879889899909919929939949959969979989991000100110021003100410051006100710081009101010111012101310141015101610171018101910201021102210231024102510261027102810291030103110321033103410351036103710381039104010411042104310441045104610471048104910501051105210531054105510561057105810591060106110621063106410651066106710681069107010711072107310741075107610771078107910801081108210831084108510861087108810891090109110921093109410951096109710981099110011011102110311041105110611071108110911101111111211131114111511161117111811191120112111221123112411251126112711281129113011311132113311341135113611371138113911401141114211431144114511461147114811491150115111521153115411551156115711581159116011611162116311641165116611671168116911701171117211731174117511761177117811791180118111821183118411851186118711881189119011911192119311941195119611971198119912001201120212031204120512061207120812091210121112121213121412151216121712181219122012211222122312241225122612271228122912301231123212331234123512361237123812391240124112421243124412451246124712481249125012511252125312541255125612571258125912601261126212631264126512661267126812691270127112721273127412751276127712781279128012811282128312841285128612871288128912901291129212931294129512961297129812991300130113021303130413051306130713081309131013111312131313141315131613171318131913201321132213231324132513261327132813291330133113321333133413351336133713381339134013411342134313441345134613471348134913501351135213531354135513561357135813591360136113621363136413651366136713681369137013711372137313741375137613771378137913801381138213831384138513861387138813891390139113921393139413951396139713981399140014011402140314041405140614071408140914101411141214131414141514161417141814191420142114221423142414251426142714281429143014311432143314341435143614371438143914401441144214431444144514461447144814491450145114521453145414551456145714581459146014611462146314641465146614671468146914701471147214731474147514761477147814791480148114821483148414851486148714881489149014911492149314941495149614971498149915001501150215031504150515061507150815091510151115121513151415151516151715181519152015211522152315241525152615271528152915301531153215331534153515361537153815391540154115421543154415451546154715481549155015511552155315541555155615571558155915601561156215631564156515661567156815691570157115721573157415751576157715781579158015811582158315841585158615871588158915901591159215931594159515961597159815991600160116021603160416051606160716081609161016111612161316141615161616171618161916201621162216231624162516261627162816291630163116321633163416351636163716381639164016411642164316441645164616471648164916501651165216531654165516561657165816591660166116621663166416651666166716681669167016711672167316741675167616771678167916801681168216831684168516861687168816891690169116921693169416951696169716981699170017011702170317041705170617071708170917101711171217131714171517161717171817191720172117221723172417251726172717281729173017311732173317341735173617371738173917401741174217431744174517461747174817491750175117521753175417551756175717581759176017611762176317641765176617671768176917701771 |
- <?xml version="1.0" encoding="UTF-8"?>
- <queryMap desc = "生产流速统计">
- <query id = "FrmrptSCLS.get_KF" desc = "生产流速--扣分说明">
- <![CDATA[
- select upper(substr(t.kftype,4,4)) as kftype,t.kf,max(t.kftype_name) as kftype_name
- from tab_rpt_kf t
- where t.isvalid='1'
- group by substr(t.kftype,4,4),t.kf
- order by substr(t.kftype,4,4),t.kf
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_DC" desc = "生产流速--待产数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no, to_char(create_time,'yyyy-MM-dd hh24:mi:ss') as create_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,planstatus,orderno,
- SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_DC where to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept_code,pline_code
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_QX" desc = "生产流速--清线数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,feed_heat_no, to_char(maxfeed_time,'yyyy-MM-dd hh24:mi:ss') as feed_time,
- to_char(maxfx_time,'yyyy-MM-dd hh24:mi:ss') as FX_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- nowork_times_days,nowork_times_days_desc,nowork_times,nowork_times_desc,
- nowork_days,nowork_days_desc ,to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_QX where to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXWT" desc = "生产流速--离线委托数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxoffline_time,'yyyy-MM-dd hh24:mi:ss') as offline_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_LX where sign='LXWT' and to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXFX" desc = "生产流速--离线完工数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxwg_time,'yyyy-MM-dd hh24:mi:ss') as wg_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_LX where sign='LXFX' and to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.get_DPSP" desc = "生产流速--待判(下线→送判)数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxin_time,'yyyy-MM-dd hh24:mi:ss') as in_time,
- to_char(maxsp_time,'yyyy-MM-dd hh24:mi:ss') as sp_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_DP where sign='DSP' and to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_DPPD" desc = "生产流速--待判(送判→判定)数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxsp_time,'yyyy-MM-dd hh24:mi:ss') as sp_time,
- to_char(maxpd_time,'yyyy-MM-dd hh24:mi:ss') as pd_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_DP where sign='DPD' and to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_FP" desc = "生产流速--废品数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxin_time,'yyyy-MM-dd hh24:mi:ss') as in_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,qz,cl_status
- from TAB_RPT_LS_FP where to_char(CREATETIME,'yyyy-MM-dd')='#today#' --and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_DC_QJ" desc = "区间生产流速--待产数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no, to_char(create_time,'yyyy-MM-dd hh24:mi:ss') as create_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,planstatus,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_DC where to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept_code,pline_code
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_QX_QJ" desc = "区间生产流速--清线数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no, to_char(maxfeed_time,'yyyy-MM-dd hh24:mi:ss') as feed_time,
- to_char(maxfx_time,'yyyy-MM-dd hh24:mi:ss') as FX_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- nowork_times_days,nowork_times_days_desc,nowork_times,nowork_times_desc,
- nowork_days,nowork_days_desc ,to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_QX where to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXWT_QJ" desc = "区间生产流速--离线委托数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxoffline_time,'yyyy-MM-dd hh24:mi:ss') as offline_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_LX where sign='LXWT'
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXFX_QJ" desc = "区间生产流速--离线完工数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxwg_time,'yyyy-MM-dd hh24:mi:ss') as wg_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_LX where sign='LXFX'
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.get_DPSP_QJ" desc = "区间生产流速--待判(下线→送判)数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxin_time,'yyyy-MM-dd hh24:mi:ss') as in_time,
- to_char(maxsp_time,'yyyy-MM-dd hh24:mi:ss') as sp_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_DP where sign='DSP'
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_DPPD_QJ" desc = "区间生产流速--待判(送判→判定)数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxsp_time,'yyyy-MM-dd hh24:mi:ss') as sp_time,
- to_char(maxpd_time,'yyyy-MM-dd hh24:mi:ss') as pd_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_DP where sign='DPD'
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_FP_QJ" desc = "区间生产流速--废品数据">
- <![CDATA[
- select processcode, area,area_code,dept,dept_code,pline_name,pline_code,heat_plan_no,
- judge_stove_no,batch_no, to_char(maxin_time,'yyyy-MM-dd hh24:mi:ss') as in_time,
- to_char(bj_time,'yyyy-MM-dd hh24:mi:ss') as bj_time,dc_hours,dc_days,kf,kfsm,orderno,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime
- from TAB_RPT_LS_FP where to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- and kf>0
- order by processcode, dept,pline_name
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_DC_KF" desc = "生产流速扣分--待产数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_DC
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_QX_KF" desc = "生产流速扣分--清线数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_QX
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXWT_KF" desc = "生产流速扣分--离线委托数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_LX
- where sign='LXWT' and kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_LXFX_KF" desc = "生产流速扣分--离线完工数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_LX
- where sign='LXFX' and kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.get_DPSP_KF" desc = "生产流速扣分--待判(下线→送判)数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_DP
- where sign='DSP' and kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_DPPD_KF" desc = "生产流速扣分--待判(送判→判定)数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_DP
- where sign='DPD' and kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_FP_KF" desc = "生产流速扣分--废品数据">
- <![CDATA[
- select max(processcode) as processcode, max(dept) as dept,max(dept_code) as dept_code
- ,pline_name,pline_code,sum(kf) as kf,to_char(CREATETIME,'yyyy-MM-dd') as createtime
- from TAB_RPT_LS_FP
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by pline_name,pline_code,to_char(CREATETIME,'yyyy-MM-dd')
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.get_TotalKF" desc = "生产流速扣分汇总">
- <![CDATA[
- select *
- from (select case when t.area_code='002001001' then '外委' when processcode='B' then '炼钢' when processcode<>'B' and area_code<>'002001002'then '轧管' else '管加工' end area
- ,case when t.area_code='002001001' then '4' when processcode='B' then '1' when processcode<>'B' and area_code<>'002001002' then '2' else '3' end area_code
- ,'1' as signxh,'DC'as sign,t.processcode,t.dept_code,max(t.dept) as dept,t.area_code as area_code1,max(t.area) as area1,
- t.pline_code,max(t.pline_name) as pline_name,to_char(createtime,'yyyy-MM-dd') as createdate,sum(kf) as kf,max(qz) as qz,to_number(sum(kf*qz)) as kfqz
- from tab_rpt_ls_dc t
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by t.processcode,t.area_code,t.dept_code,t.pline_code,to_char(createtime,'yyyy-MM-dd')
- union
- select case when t.area_code='002001001' then '外委' when processcode='B' then '炼钢' when processcode<>'B' and area_code<>'002001002'then '轧管' else '管加工' end area
- ,case when t.area_code='002001001' then '4' when processcode='B' then '1' when processcode<>'B' and area_code<>'002001002' then '2' else '3' end area_code
- ,'2' as signxh,'QX'as sign,t.processcode,t.dept_code,max(t.dept) as dept,t.area_code as area_code1,max(t.area) as area1,
- t.pline_code,max(t.pline_name) as pline_name,to_char(createtime,'yyyy-MM-dd'),sum(kf),max(qz) as qz,to_number(sum(kf*qz)) as kfqz
- from tab_rpt_ls_qx t
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by t.processcode,t.area_code,t.dept_code,t.pline_code,to_char(createtime,'yyyy-MM-dd')
- union
- select case when t.area_code='002001001' then '外委' when processcode='B' then '炼钢' when processcode<>'B' and area_code<>'002001002'then '轧管' else '管加工' end area
- ,case when t.area_code='002001001' then '4' when processcode='B' then '1' when processcode<>'B' and area_code<>'002001002' then '2' else '3' end area_code
- ,case when t.sign='DSP' then '3' else '4' end as signxh,t.sign,t.processcode,t.dept_code,max(t.dept) as dept,t.area_code as area_code1,max(t.area) as area1,
- t.pline_code,max(t.pline_name) as pline_name,to_char(createtime,'yyyy-MM-dd'),sum(kf),max(qz) as qz,to_number(sum(kf*qz)) as kfqz
- from tab_rpt_ls_dp t
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by t.sign,t.processcode,t.area_code,t.dept_code,t.pline_code,to_char(createtime,'yyyy-MM-dd')
- union
- select case when t.area_code='002001001' then '外委' when processcode='B' then '炼钢' when processcode<>'B' and area_code<>'002001002'then '轧管' else '管加工' end area
- ,case when t.area_code='002001001' then '4' when processcode='B' then '1' when processcode<>'B' and area_code<>'002001002' then '2' else '3' end area_code
- ,case when t.sign='LXWT' then '5' else '6' end as signxh,t.sign,t.processcode,t.dept_code,max(t.dept) as dept,t.area_code as area_code1,max(t.area) as area1,
- t.pline_code,max(t.pline_name) as pline_name,to_char(createtime,'yyyy-MM-dd'),sum(kf),max(qz) as qz,to_number(sum(kf*qz)) as kfqz
- from tab_rpt_ls_lx t
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by t.sign,t.processcode,t.area_code,t.dept_code,t.pline_code,to_char(createtime,'yyyy-MM-dd')
- union
- select case when t.area_code='002001001' then '外委' when processcode='B' then '炼钢' when processcode<>'B' and area_code<>'002001002'then '轧管' else '管加工' end area
- ,case when t.area_code='002001001' then '4' when processcode='B' then '1' when processcode<>'B' and area_code<>'002001002' then '2' else '3' end area_code
- ,'7' as signxh,'FP' as sign,t.processcode,t.dept_code,max(t.dept) as dept,t.area_code as area_code1,max(t.area) as area1,
- t.pline_code,max(t.pline_name) as pline_name,to_char(createtime,'yyyy-MM-dd'),sum(kf),max(qz) as qz,to_number(sum(kf*qz)) as kfqz
- from tab_rpt_ls_fp t
- where kf>0
- and to_char(CREATETIME,'yyyy-MM-dd')>='#fromday#' and to_char(CREATETIME,'yyyy-MM-dd')<='#today#'
- group by t.processcode,t.area_code,t.dept_code,t.pline_code,to_char(createtime,'yyyy-MM-dd') )a
- order by area_code,dept,processcode,pline_name,createdate
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_SCZQ_PZ" desc = "生产周期--品种数据">
- <![CDATA[
- with v_sczq as (select round((to_date(to_char(t.judge_tolresult_time,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')-to_date(to_char(t.zg_feedtime,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')),1) as workhours,t.*
- from tab_rpt_ls_sczq t
- where not material_no is null and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')>='#fromday#' and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')<='#today#')
- select a.produccode,a.producname
- ,(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode)) as min_whole_backlog
-
- ,(select min(workhours) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as minwhole_backlog_minworkhours
- ,(select max(workhours) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as minwhole_backlog_maxworkhours
-
- ,(select round(avg(workhours),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_avgworkhours
-
- ,(select round(sum(workhours*act_count)/sum(act_count),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_ajqworkhours
- ,(select round(STDDEV (workhours),1) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as minwholelog_STDDEVwhours --标准差
- ,(select sum(act_count) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as minwholelog_act_count
- ,(select count(judge_stove_no) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as minwholelog_lcount
-
- ,(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode)) as max_whole_backlog
- ,(select min(workhours) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwhole_backlog_minworkhours
- ,(select max(workhours) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwhole_backlog_maxworkhours
- ,(select round(avg(workhours),1) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwhole_backlog_avgworkhours
-
- ,(select round(sum(workhours*act_count)/sum(act_count),1) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwhole_backlog_ajqworkhours
-
- ,(select round(STDDEV(workhours),1) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwholelog_STDDEVwhours --标准差
-
- ,(select sum(z.act_count) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwholelog_act_count
-
- ,(select count(judge_stove_no) from v_sczq z
- where z.produccode=a.produccode
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode))) as maxwholelog_lcount
-
- /*,(select MIN(length(y.whole_backlog)) from v_sczq y
- where y.produccode=a.produccode) as minlen
- ,(select max(length(y.whole_backlog)) from v_sczq y
- where y.produccode=a.produccode) as maxlen*/
-
- ,(select min(workhours) from v_sczq y
- where y.produccode=a.produccode) as minworkhours
- ,(select max(workhours) from v_sczq y
- where y.produccode=a.produccode) as maxworkhours
- ,(select round(avg(workhours),1) from v_sczq y
- where y.produccode=a.produccode) as avgworkhours
-
- ,(select round(sum(workhours*act_count)/sum(act_count),1) from v_sczq y
- where y.produccode=a.produccode) as avgjqworkhours
-
- ,(select round(STDDEV(workhours),1) from v_sczq y
- where y.produccode=a.produccode) as STDDEVwhours --标准差
-
- ,(select sum(act_count) from v_sczq y
- where y.produccode=a.produccode) as act_count
-
- ,(select count(judge_stove_no) from v_sczq y
- where y.produccode=a.produccode) as lcount
-
- from (SELECT * FROM v_sczq WHERE ROWID IN (
- SELECT MIN(ROWID) FROM v_sczq t GROUP BY t.produccode)) a
- order by (select min(workhours) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode),a.produccode
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_SCZQ_WL" desc = "生产周期--物料数据">
- <![CDATA[
- with v_sczq as (select round((to_date(to_char(t.judge_tolresult_time,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')-to_date(to_char(t.zg_feedtime,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')),1) as workhours,t.*
- from tab_rpt_ls_sczq t
- where not material_no is null and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')>='#fromday#' and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')<='#today#')
- select a.produccode,a.producname,a.material_no,a.material_name
- ,(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no)) as min_whole_backlog
-
- ,(select min(workhours) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_minworkhours
- ,(select max(workhours) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_maxworkhours
-
- ,(select round(avg(workhours),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_avgworkhours
- ,(select round(sum(workhours*act_count)/sum(act_count),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwhole_backlog_ajqworkhours
-
- ,(select round(STDDEV (workhours),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwholelog_STDDEVwhours --标准差
- ,(select sum(act_count) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwholelog_act_count
- ,(select count(judge_stove_no) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select min(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as minwholelog_lcount
-
- ,(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no)) as max_whole_backlog
- ,(select min(workhours) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwhole_backlog_minworkhours
- ,(select max(workhours) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwhole_backlog_maxworkhours
- ,(select round(avg(workhours),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwhole_backlog_avgworkhours
- ,(select round(sum(workhours*act_count)/sum(act_count),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwhole_backlog_ajqworkhours
- ,(select round(STDDEV(workhours),1) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwholelog_STDDEVwhours --标准差
-
- ,(select sum(act_count) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwholelog_act_count
- ,(select count(judge_stove_no) from v_sczq z
- where z.produccode=a.produccode and z.material_no=a.material_no
- and z.whole_backlog=(select max(x.whole_backlog) from v_sczq x
- where x.produccode=a.produccode and x.material_no=a.material_no
- and length(x.whole_backlog)=(select max(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no))) as maxwholelog_lcount
-
- /*,(select MIN(length(y.whole_backlog)) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as minlenwhole_backlog
- ,(select max(length(y.whole_backlog)) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as maxlenwhole_backlog*/
-
- ,(select min(workhours) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as minworkhours
- ,(select max(workhours) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as maxworkhours
- ,(select round(avg(workhours),1) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as avgworkhours
-
- ,(select round(sum(workhours*act_count)/sum(act_count),2) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as avgjqworkhours
-
- ,(select round(STDDEV(workhours),1) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as STDDEVwhours --标准差
-
- ,(select sum(y.act_count) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as act_count
- ,(select count(judge_stove_no) from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no) as lcount
-
- from (SELECT * FROM v_sczq WHERE ROWID IN (
- SELECT MIN(ROWID) FROM v_sczq t GROUP BY t.produccode,t.producname,t.material_no,t.material_name )) a
- order by (select min(workhours) whole_backlog_len from v_sczq y
- where y.produccode=a.produccode and y.material_no=a.material_no),a.produccode,a.material_no
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_SCZQ_L" desc = "生产周期--炉数据">
- <![CDATA[
- with v_sczq as (select round((to_date(to_char(t.judge_tolresult_time,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')-to_date(to_char(t.zg_feedtime,'yyyy-MM-dd hh24:mi:ss'),'yyyy-MM-dd hh24:mi:ss')),1) as workhours,t.*
- from tab_rpt_ls_sczq t
- where material_no='#material_no#' and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')>='#fromday#' and to_char(JUDGE_TOLRESULT_TIME,'yyyy-MM-dd')<='#today#')
-
- select pline_name as 产线, judge_stove_no as 判定炉号,batch_no as 批号, whole_backlog as 流程码,workhours as "生产周期(天)",
- to_char(judge_tolresult_time,'yyyy-MM-dd hh24:mi:ss') as 综合判定时间,
- to_char(zg_feedtime,'yyyy-MM-dd hh24:mi:ss') as 轧管上料时间, zg_feed_judge_stove_no as 轧管上料炉号,
- produccode as 品种代码,producname as 品名,material_no as 物料码, material_name as 物料名称
- ,act_count as 支,nvl(act_weight,act_theory_weight) as 吨, steelname as 钢级,
- gradename as 钢种,spec_name as 规格,model_desc as 扣型,std_name as 标准,std_style_desc as 标准类别,
- act_len_min||'-'||act_len_max as 长度范围,act_len as 实际长度, pro_order_no as 合同号,process_status as 热处理状态
-
- /* steelcode, gradecode, spec_code, model_code, std_code, std_style,target, ct_dimater,act_height,
- pline_code, load_judge_stove_no,load_batch_no,zp_m_lh,zp_coll, process_code, jugde_apply_code,
- jugde_apply_sequeno,quality_group,batch_groud_no, belong_name_jugde, ord_ln_dly_pk,
- input_weight,input_count,output_weight,output_count,bal_year_month,is_all_scrap,is_carry_voer,
- stove_no,steel_standrad,heat_plan_no,zbs_flag,createtime */
-
- from v_sczq
- order by workhours,produccode,material_no
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_SCLS_kf" desc = "流速扣分">
- <![CDATA[
- select id, kftype, isvalid, to_char(startime,'yyyy-MM-dd') as startime,
- endtime, processcode, min_range, max_range, kf, kftype_name ,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,
- to_char(updatetime,'yyyy-MM-dd hh24:mi:ss') as updatetime
- from tab_rpt_kf
- where ('#kftype#'='1' or kftype='#kftype#')
- ]]>
- </query>
- <query id = "FrmrptSCLS.update_SCLS_kf" desc = "流速扣分_update">
- <![CDATA[
- update tab_rpt_kf
- set kftype='#kftype#', startime=to_date('#startime#','yyyy-MM-dd'),
- processcode='#processcode#', min_range=#min_range#, max_range=#max_range#, kf=#kf#,
- kftype_name='#kftype_name#' , updatetime=sysdate
- where id='#id#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.insert_SCLS_kf" desc = "流速扣分_insert">
- <![CDATA[
- insert into tab_rpt_kf(id,kftype, isvalid, startime,processcode,
- min_range, max_range, kf,kftype_name, createtime)
- values ('#id#','#kftype#','0', to_date('#startime#','yyyy-MM-dd'),'#processcode#',
- #min_range#, #max_range#, #kf#, '#kftype_name#' , sysdate)
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.delete_SCLS_kf" desc = "流速扣分_delete">
- <![CDATA[
- delete tab_rpt_kf
- where id='#id#' and isvalid='0'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.isvalid_SCLS_kf" desc = "流速扣分_isvalid">
- <![CDATA[
- update tab_rpt_kf set isvalid='#newisvalid#'
- where id='#id#' and isvalid='#oldisvalid#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_SCLS_kffjx1" desc = "流速扣分-附加项1">
- <![CDATA[
- select id,kftype,fjtype,fjtype_name,processcode,fj_value,isvalid,
- to_char(startime,'yyyy-MM-dd') as startime,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,
- to_char(updatetime,'yyyy-MM-dd hh24:mi:ss') as updatetime
- from tab_rpt_kffj
- where ('#kftype#'='1' or kftype='#kftype#')
- ]]>
- </query>
- <query id = "FrmrptSCLS.update_SCLS_kffjx1" desc = "流速扣分-附加项1_update">
- <![CDATA[
- update tab_rpt_kffj
- set kftype='#kftype#',fjtype='#fjtype#',fjtype_name='#fjtype_name#',processcode='#processcode#',fj_value=#fj_value#,
- startime=to_date('#startime#','yyyy-MM-dd'),updatetime=sysdate
- where id='#id#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.insert_SCLS_kffjx1" desc = "流速扣分-附加项1_insert">
- <![CDATA[
- insert into tab_rpt_kffj(id,kftype,fjtype,fjtype_name,processcode,fj_value,
- isvalid,startime,createtime)
- values ('#id#','#kftype#','#fjtype#','#fjtype_name#','#processcode#', #fj_value#,
- '0', to_date('#startime#','yyyy-MM-dd'), sysdate)
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.delete_SCLS_kffjx1" desc = "流速扣分-附加项1_delete">
- <![CDATA[
- delete tab_rpt_kffj
- where id='#id#' and isvalid='0'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.isvalid_SCLS_kffjx1" desc = "流速扣分-附加项1_isvalid">
- <![CDATA[
- update tab_rpt_kffj set isvalid='#newisvalid#'
- where id='#id#' and isvalid='#oldisvalid#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.get_SCLS_kffjx2" desc = "流速扣分-附加项2">
- <![CDATA[
- select id,kftype,noworktime_desc,processcode,pline_code,pline_name,
- nowork_times,nowork_days,isvalid,
- to_char(startime,'yyyy-MM-dd') as startime,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,
- to_char(updatetime,'yyyy-MM-dd hh24:mi:ss') as updatetime
- from tab_rpt_kf_works
- where ('#kftype#'='1' or kftype='#kftype#')
- ]]>
- </query>
- <query id = "FrmrptSCLS.update_SCLS_kffjx2" desc = "流速扣分-附加项2_update">
- <![CDATA[
- update tab_rpt_kf_works
- set kftype='#kftype#',noworktime_desc='#noworktime_desc#',
- processcode='#processcode#',pline_code='#pline_code#',pline_name='#pline_name#',
- nowork_days=#nowork_days#,nowork_times=#nowork_times#,
- startime=to_date('#startime#','yyyy-MM-dd'),updatetime=sysdate
- where id='#id#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.insert_SCLS_kffjx2" desc = "流速扣分-附加项2_insert">
- <![CDATA[
- insert into tab_rpt_kf_works(id,kftype,noworktime_desc,
- processcode,pline_code,pline_name,nowork_days,nowork_times,
- isvalid,startime,createtime)
- values ('#id#','#kftype#','#noworktime_desc#',
- '#processcode#','#pline_code#','#pline_name#',#nowork_days#,#nowork_times#,
- '0', to_date('#startime#','yyyy-MM-dd'), sysdate)
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.delete_SCLS_kffjx2" desc = "流速扣分-附加项2_delete">
- <![CDATA[
- delete tab_rpt_kf_works
- where id='#id#' and isvalid='0'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.isvalid_SCLS_kffjx2" desc = "流速扣分-附加项2_isvalid">
- <![CDATA[
- update tab_rpt_kf_works set isvalid='#newisvalid#'
- where id='#id#' and isvalid='#oldisvalid#'
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.get_SCLS_kfqz" desc = "流速扣分权重_">
- <![CDATA[
- select id, qztype, isvalid, to_char(startime,'yyyy-MM-dd') as startime, qz, qztype_name ,
- to_char(createtime,'yyyy-MM-dd hh24:mi:ss') as createtime,
- to_char(updatetime,'yyyy-MM-dd hh24:mi:ss') as updatetime
- from tab_rpt_kfqz
- ]]>
- </query>
- <query id = "FrmrptSCLS.update_SCLS_kfqz" desc = "流速扣分权重_update">
- <![CDATA[
- update tab_rpt_kfqz
- set qztype='#qztype#', startime=to_date('#startime#','yyyy-MM-dd'), qz=#qz#,
- qztype_name='#qztype_name#' , updatetime=sysdate
- where id='#id#'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.insert_SCLS_kfqz" desc = "流速扣分权重_insert">
- <![CDATA[
- insert into tab_rpt_kfqz(id,qztype, isvalid, startime,qz,qztype_name, createtime)
- values ('#id#','#qztype#','0', to_date('#startime#','yyyy-MM-dd'),#qz#, '#qztype_name#', sysdate)
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.delete_SCLS_kfqz" desc = "流速扣分权重_delete">
- <![CDATA[
- delete tab_rpt_kfqz
- where id='#id#' and isvalid='0'
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.isvalid_SCLS_kfqz" desc = "流速扣分权重_isvalid">
- <![CDATA[
- update tab_rpt_kfqz set isvalid='#newisvalid#'
- where id='#id#' and isvalid='#oldisvalid#'
- ]]>
- </query>
- <query id = "FrmrptSCLS.get_pline" desc = "产线">
- <![CDATA[
- select process_code,pline_code,pline_name from com_base_pline t
- where t.validflag='1'
- order by process_code,pline_name
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.importDC" desc = "导入待产数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_DC;
- commit;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- maxcreate_time, bj_time, dc_hours, dc_days, kf, kfsm, max_planstatus as planstatus ,maxorderno as orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_d;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_e;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_f;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_g;
- commit;
-
- delete from TAB_RPT_LS_DC
- where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_DC where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from TAB_RPT_temp_LS_DC
- where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd');
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectDC" desc = "导入待产数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_DC where to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
- <query id = "FrmrptSCLS.importQX" desc = "导入待清线数据">
- <![CDATA[
- BEGIN
- delete from TAB_RPT_temp_LS_QX;
- commit;
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no,judge_stove_no, null as batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, max_zxz as zxz, maxorderno as orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_d;
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_e;
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_f;
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_g;
- commit;
-
- delete from TAB_RPT_LS_QX
- where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_QX where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_QX (processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no
- from TAB_RPT_temp_LS_QX where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd');
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectQX" desc = "导入待清线数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_QX where to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.importLXWT" desc = "导入离线待委托数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_LX;
- commit;
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_d;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_e;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_f;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time,to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_g;
- commit;
-
- delete from TAB_RPT_LS_LX
- where sign='LXWT' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_LX where sign='LXWT' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_LX (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz
- from TAB_RPT_temp_LS_LX
- where sign='LXWT' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd') ;
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectLXWT" desc = "导入离线待委托数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_LX where sign='LXWT' and to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.importLXFX" desc = "导入离线待返线数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_LX;
- commit;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_d;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_e;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_f;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_g;
- commit;
-
- delete from TAB_RPT_LS_LX
- where sign='LXFX' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_LX where sign='LXFX' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz
- from TAB_RPT_temp_LS_LX
- where sign='LXFX' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd') ;
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectLXFX" desc = "导入离线待返线数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_LX where sign='LXFX' and to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.importDPDSP" desc = "导入下线待送判数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_DP;
- commit;
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,null as minpd_time,null as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_b;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_d;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_e;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_f;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_g;
- commit;
-
- delete from TAB_RPT_LS_DP
- where sign='DSP' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_DP where sign='DSP' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')) ;
-
- insert into TAB_RPT_LS_DP (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz
- from TAB_RPT_temp_LS_DP
- where sign='DSP' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd');
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectDPDSP" desc = "导入下线待送判数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_DP where sign='DSP' and to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.importDPDPD" desc = "导入下线待判定数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_DP;
- commit;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode,area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_b;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_d;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_e;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_f;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_g;
- commit;
-
- delete from TAB_RPT_LS_DP
- where sign='DPD' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_DP where sign='DPD' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_DP (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz
- from TAB_RPT_temp_LS_DP
- where sign='DPD' and to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd') ;
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectDPDPD" desc = "导入下线待判定数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_DP where sign='DPD' and to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.importFP" desc = "导入废品待处理数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_FP;
- commit;
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode,area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_b;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_d;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_e;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_f;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_g;
- commit;
-
- delete from TAB_RPT_LS_FP
- where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and exists(select 1 from TAB_RPT_temp_LS_FP where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd'));
-
- insert into TAB_RPT_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz
- from TAB_RPT_temp_LS_FP where to_char(createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd');
- commit;
- end;
- ]]>
- </query>
- <query id = "FrmrptSCLS.selectFP" desc = "导入废品待处理数据查询">
- <![CDATA[
- select count(processcode) from TAB_RPT_LS_FP where to_char(CREATETIME,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.UpdateDC" desc = "更新待产数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_DC;
- commit;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- maxcreate_time, bj_time, dc_hours, dc_days, kf, kfsm, max_planstatus as planstatus ,maxorderno as orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_d;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_e;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_f;
- insert into TAB_RPT_temp_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,sysdate,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from v_rpt_scls_dc_g;
- commit;
-
- update TAB_RPT_LS_DC a set a.cl_status='1'
- where a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DC b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and a.heat_plan_no=b.heat_plan_no and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete
- from TAB_RPT_LS_DC a
- where a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DC b
- where b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and a.heat_plan_no=b.heat_plan_no and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- insert into TAB_RPT_LS_DC(processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code,heat_plan_no,judge_stove_no,
- create_time, bj_time, dc_hours, dc_days, 0 as kf, kfsm, planstatus ,orderno,createtime,SPEC_NAME ,STEELNAME,PRODUCNAME,MODEL_DESC
- ,PLN_OUTSINGLE_NUM,PLN_OUTSINGLE_W,qz
- from TAB_RPT_temp_LS_DC a
- where not exists (select 1 from TAB_RPT_LS_DC b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and a.heat_plan_no=b.heat_plan_no and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
-
- <query id = "FrmrptSCLS.UpdateQX" desc = "更新清线数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_QX;
- commit;
-
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no,judge_stove_no, null as batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, max_zxz as zxz, maxorderno as orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_d;
-
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_e;
-
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_f;
-
- insert into TAB_RPT_temp_LS_QX(processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,sysdate,qz,feed_heat_no
- from v_rpt_scls_qx_g;
- commit;
-
- update TAB_RPT_LS_QX a set a.cl_status='1'
- where a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_QX b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_QX a
- where a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_QX b
- where b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
-
- insert into TAB_RPT_LS_QX (processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minfeed_time, maxfeed_time, minfx_time, maxfx_time, bj_time, dc_hours, dc_days, dc_hours_xz, dc_days_xz,
- 0 as kf, kfsm, zxz, orderno, nowork_times_days, nowork_times, nowork_days,
- nowork_days_all, nowork_times_days_desc, nowork_times_desc, nowork_days_desc,createtime,qz,feed_heat_no
- from TAB_RPT_temp_LS_QX a
- where not exists (select 1 from TAB_RPT_LS_QX b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.UpdateDPDSP" desc = "更新待送判数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_DP;
- commit;
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,null as minpd_time,null as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_b;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_d;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_e;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_f;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DSP' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time,minsp_time, maxsp_time,to_date(null) as minpd_time, to_date(null) as maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dpsp_g;
- commit;
-
- update TAB_RPT_LS_DP a set a.cl_status='1'
- where sign='DSP' and a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DP b
- where b.sign='DSP' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_DP a
- where sign='DSP' and a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DP b
- where b.sign='DSP' and b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- insert into TAB_RPT_LS_DP (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, 0 as kf, kfsm, dspz, orderno,createtime,qz
- from TAB_RPT_temp_LS_DP a
- where a.sign='DSP' and not exists (select 1 from TAB_RPT_LS_DP b
- where b.sign='DSP' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.UpdateDPDPD" desc = "更新待判定数据">
- <![CDATA[
- begin
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode,area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_b;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_d;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_e;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_f;
-
- insert into TAB_RPT_temp_LS_DP(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select 'DPD' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minin_time, to_date(null) as maxin_time,minsp_time, maxsp_time, minpd_time, maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,sysdate,qz
- from v_rpt_scls_dppd_g;
- commit;
-
-
- update TAB_RPT_LS_DP a set a.cl_status='1'
- where sign='DPD' and a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DP b
- where b.sign='DPD' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_DP a
- where sign='DPD' and a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_DP b
- where b.sign='DPD' and b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
-
- insert into TAB_RPT_LS_DP (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, kf, kfsm, dspz, orderno,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, minsp_time, maxsp_time,minpd_time,maxpd_time, bj_time, dc_hours, dc_days, 0 as kf, kfsm, dspz, orderno,createtime,qz
- from TAB_RPT_temp_LS_DP a
- where a.sign='DPD' and not exists (select 1 from TAB_RPT_LS_DP b
- where b.sign='DPD' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.UpdateLXWT" desc = "更新离线待委托数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_LX;
- commit;
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_d;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_e;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,wgz, orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time, to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_f;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXWT' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minoffline_time, maxoffline_time,to_date(null) as minwg_time,to_date(null) as maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz,null as wgz, orderno,null as jcx,sysdate,qz
- from v_rpt_scls_lxww_g;
- commit;
-
- update TAB_RPT_LS_LX a set a.cl_status='1'
- where sign='LXWT' and a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_LX b
- where b.sign='LXWT' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_LX a
- where sign='LXWT' and a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_LX b
- where b.sign='LXWT' and b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
-
- insert into TAB_RPT_LS_LX (sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days,0 as kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz
- from TAB_RPT_temp_LS_LX a
- where a.sign='LXWT' and not exists (select 1 from TAB_RPT_LS_LX b
- where b.sign='LXWT' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.UpdateLXFX" desc = "更新离线待返线数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_LX;
- commit;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_d;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_e;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz,orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_f;
-
- insert into TAB_RPT_temp_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days,kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select 'LXFX' as sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- to_date(null) as minoffline_time, to_date(null) as maxoffline_time,minwg_time, maxwg_time, bj_time, dc_hours, dc_days, kf, kfsm,null as lxz, wgz, orderno, jcx,sysdate,qz
- from v_rpt_scls_lxfx_g;
- commit;
-
- update TAB_RPT_LS_LX a set a.cl_status='1'
- where sign='LXFX' and a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_LX b
- where b.sign='LXFX' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_LX a
- where sign='LXFX' and a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_LX b
- where b.sign='LXFX' and b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- insert into TAB_RPT_LS_LX(sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days, kf, kfsm, lxz, wgz, orderno,jcx,createtime,qz)
- select sign,processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no,batch_no,
- minoffline_time, maxoffline_time, minwg_time,maxwg_time,bj_time, dc_hours, dc_days,0 as kf,kfsm, lxz, wgz, orderno,jcx,createtime,qz
- from TAB_RPT_temp_LS_LX a
- where a.sign='LXFX' and not exists (select 1 from TAB_RPT_LS_LX b
- where b.sign='LXFX' and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.UpdateFP" desc = "更新待处理废品数据">
- <![CDATA[
- begin
- delete from TAB_RPT_temp_LS_FP;
- commit;
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode,area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_b;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, null as heat_plan_no, judge_stove_no, null as batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_d;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_e;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_f;
-
- insert into TAB_RPT_temp_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode, area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,sysdate,qz
- from v_rpt_scls_fp_g;
- commit;
-
- update TAB_RPT_LS_FP a set a.cl_status='1'
- where a.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_FP b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- delete from TAB_RPT_LS_FP a
- where a.kf=0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(sysdate,'yyyy-MM-dd')
- and not exists (select 1 from TAB_RPT_temp_LS_FP b
- where b.kf>0 and to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
-
- insert into TAB_RPT_LS_FP(processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days, kf, kfsm, wsqz, orderno,createtime,qz)
- select processcode,area, area_code, dept, dept_code, pline_name, pline_code, heat_plan_no, judge_stove_no, batch_no,
- minin_time, maxin_time, bj_time, dc_hours, dc_days,0 as kf, kfsm, wsqz, orderno,createtime,qz
- from TAB_RPT_temp_LS_FP a
- where not exists (select 1 from TAB_RPT_LS_FP b
- where to_char(a.createtime,'yyyy-MM-dd')=to_char(b.createtime,'yyyy-MM-dd')
- and a.processcode=b.processcode and a.pline_code=b.pline_code
- and (a.heat_plan_no is null and b.heat_plan_no is null or a.heat_plan_no=b.heat_plan_no) and a.judge_stove_no=b.judge_stove_no);
- commit;
- end;
- ]]>
- </query>
-
- <query id = "FrmrptSCLS.getHTZQ" desc = "查询合同生产周期数据">
- <![CDATA[
- select d.PRO_PLAN_ID as 轧管订单编号
- ,d.GX_PLAN_NO as 工序排产序号
- ,d.ORDER_SOURCE as 主合同来源
- ,d.ORD_LN_DLY_PK as 主交货编码PK
- ,d.PLN_DIVIDE_ID as 主排产流水号
- ,d.ORDER_NO ||'/'|| d.ORDER_SEQ as 合同号
- ,d.PLINE_NAME as 产线
- ,d.GRADENAME as 钢种
- ,d.DIAMETER_GP as 管坯直径
- ,d.PASS_NAME as 孔型
- ,d.WEIGTH_S as 排产重量
- ,d.IF_MONITOR_ZG as 是否轧管监制
- ,d.CRAFT_FILE_NO as 工艺文件号
- ,d.CRAFT_FILE_MAN as 工艺文件责任人
- ,d.PRO_MONTH as 生产年月
- ,to_char(d.PLAN_TIME_B ,'yyyy-MM-dd hh24:mi:ss') as 计划开始时间
- ,d.EXE_STATUS as 执行状态
- ,d.GPREQ_ID as 管坯需求编号
- ,d.OUTDIAMETER_ZG as 轧管名义外径
- ,d.WALLTHICK_ZG as 轧管名义壁厚
- ,case when d.OUTDIAMETER_ZG < '90' then '小' else null end as 小管
- ,d.PROCESS_DESC_C as 二级工序名
- ,f.GROUP_JGX as 加工组
- ,f.GROUP_RCL as 热处理组
- ,f.PLAN_TOT_LEN_D as 分配总长米
- ,f.PLANSTATUS as 排产状态
- ,f.PRIORITY as 合同紧急度
- ,f.PRIORITY_MEMO as 紧急度备注
- ,f.PROC_DESC_C_RCL as 热处理二级工序
- ,f.BJ_TYPE as 变径类型
- ,f.ABC as 产销ABC
- ,f.VERSION_NO as 合同下发版次
- ,f.GRADECODE_ALL as 钢种可选
- ,f.ISSUED_TIME as 下发日期
- ,to_date(substr(f.VERSION_NO,0,8),'yyyyMMdd') as 下发版次日期
- ,to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd')-to_date(substr(f.VERSION_NO,0,8),'yyyyMMdd') as 下发版次天数
- ,f.ISSUED_MAN as 下发人
- ,o.PRODUCNAME as 品名描述
- ,o.STEELNAME as 钢级牌号
- ,o.SPEC_NAME as 产品规格描述
- ,o.MODEL_DESC as 扣型描述
- ,o.BUYER_NAME as 客户名称
- ,o.STD_STYLE_DESC as 标准类别描述
- ,o.ORDERFROM as 合同来源
- ,o.FINAL_USER_DESC as 最终用户描述
- ,o.BUYER_ID as 客户编号
- ,o.ORDER_ADD_DESC as 附加要求描述
- ,k.MARKET_SYS as 市场系统
- ,k.ABRVITION as 客户简称
- ,d.GPREQ_NUM as 需求支
- ,d.GPREQ_WEIGHT as 需求吨
- ,d.WEIGTH_S_MIN as 排产最小吨
- ,d.PLANS_NUM as 计划产出支
- ,d.PROD_STANDARD as 生产标准
- ,d.DECISION as 判定字头
- ,d.OUTS_BILLET_FL as 外购坯
- ,d.GRADENAME_LK as
- ,d.BATCHED_WT as 上料吨
- ,d.BATCHED_NUM as 上料支
- ,(select sum(nvl(PLAN_INDOUBLE_NUM,0)*nvl(CUT_NUM_GP,0)) FROM PLN_ZY_ZG_C a
- where exists (select 1 from PLN_ZY_ZG_M y where a.HEAT_PLAN_NO=y.HEAT_PLAN_NO and y.PLANSTATUS IN ('00','10') )
- and d.PRO_PLAN_ID=a.PRO_PLAN_ID and d.GX_PLAN_NO=a.GX_PLAN_NO) as 装炉支
- ,(select sum(nvl(PLAN_INDOUBLE_WT,0)) FROM PLN_ZY_ZG_C a
- where exists (select 1 from PLN_ZY_ZG_M y where a.HEAT_PLAN_NO=y.HEAT_PLAN_NO and y.PLANSTATUS IN ('00','10') )
- and d.PRO_PLAN_ID=a.PRO_PLAN_ID and d.GX_PLAN_NO=a.GX_PLAN_NO) as 装炉吨
- ,(select sum(REAL_INDOUBLE_NUM*CUT_NUM_GP) FROM PLN_ZY_ZG_C a
- where exists (select 1 from PLN_ZY_ZG_M y where a.HEAT_PLAN_NO=y.HEAT_PLAN_NO and y.PLANSTATUS IN ('20','30','40'))
- and d.PRO_PLAN_ID=a.PRO_PLAN_ID and d.GX_PLAN_NO=a.GX_PLAN_NO) as 出库支
- ,(select sum(REAL_INDOUBLE_WT) FROM PLN_ZY_ZG_C a
- where exists (select 1 from PLN_ZY_ZG_M y where a.HEAT_PLAN_NO=y.HEAT_PLAN_NO and y.PLANSTATUS IN ('20','30','40'))
- and d.PRO_PLAN_ID=a.PRO_PLAN_ID and d.GX_PLAN_NO=a.GX_PLAN_NO) as 出库吨
- ,(select sum(ACT_COUNT * FIX_NUM) FROM MAT_GP_M a
- where a.Mat_Status = '80150101' and d.PRO_PLAN_ID=a.PRO_PLAN_ID_ZG and d.GX_PLAN_NO =a.GX_PLAN_NO_ZG) as 待判支
- ,(select sum(ACT_WEIGHT) FROM MAT_GP_M a
- where a.Mat_Status = '80150101' and d.PRO_PLAN_ID=a.PRO_PLAN_ID_ZG and d.GX_PLAN_NO =a.GX_PLAN_NO_ZG) as 待判吨
- ,(select sum(nvl(PLN_INSINGLE_NUM , 0 ))
- FROM PLN_ZY_ZG_M h
- where d.PRO_PLAN_ID=h.PRO_PLAN_ID and d.GX_PLAN_NO =h.GX_PLAN_NO) as LJ吨
- ,(select sum(nvl(PLN_INSINGLE_WT , 0))
- FROM PLN_ZY_ZG_M h
- where d.PRO_PLAN_ID=h.PRO_PLAN_ID and d.GX_PLAN_NO =h.GX_PLAN_NO) as LJ吨
- ,case when round(months_between(to_date(to_char(d.PLAN_TIME_B,'yyyy-MM-dd'),'yyyy-MM-dd'),to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd'))) < 0 then '历史'
- when round(months_between(to_date(to_char(d.PLAN_TIME_B,'yyyy-MM-dd'),'yyyy-MM-dd'),to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd'))) =0 then 'N'
- when round(months_between(to_date(to_char(d.PLAN_TIME_B,'yyyy-MM-dd'),'yyyy-MM-dd'),to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd'))) =1 then 'N+1'
- when round(months_between(to_date(to_char(d.PLAN_TIME_B,'yyyy-MM-dd'),'yyyy-MM-dd'),to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd'))) =2 then 'N+2'
- when trunc(months_between(to_date(to_char(d.PLAN_TIME_B,'yyyy-MM-dd'),'yyyy-MM-dd'),to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd'))) >2 then 'N+n'
- END as 排产年月
- from PLN_ORDER_ZG_S d
- inner join (select ORD_LN_DLY_PK,PLN_DIVIDE_ID,GROUP_JGX,GROUP_RCL,PLAN_TOT_LEN_D,PLANSTATUS,PRIORITY,PRIORITY_MEMO,PROC_DESC_C_RCL
- ,BJ_TYPE,ABC,VERSION_NO,GRADECODE_ALL,ISSUED_TIME,ISSUED_MAN
- from PLN_SALEORD_PROC where to_date(substr(VERSION_NO,0,8),'yyyyMMdd')<to_date(to_char(sysdate,'yyyy-MM-dd'),'yyyy-MM-dd')-#days#) f on d.ORD_LN_DLY_PK =f.ORD_LN_DLY_PK and d.PLN_DIVIDE_ID= f.PLN_DIVIDE_ID
- left join PLN_SALEORD o on d.ORD_LN_DLY_PK =o.ORD_LN_DLY_PK
- left join SLM_BASE_CUSTOMER k on o.BUYER_ID=k.CUSTOMER_NO
- left join (select PRODUCNAME,STEELNAME,SPEC_NAME,MODEL_DESC,STD_STYLE_DESC,TP_SERIES,SPECIAL_MODEL
- ,UPMARKET_PRODUCT,HIGH_ADDITIONAL_PRODUCT,MATERIAL_TYPE_MAX_DESC,MATERIAL_TYPE_MID_DESC,MATERIAL_TYPE_MIN_DESC
- from SLM_BASE_MATERIAL)y on y.PRODUCNAME=o.PRODUCNAME and y.STEELNAME=o.STEELNAME and y.SPEC_NAME=o.SPEC_NAME
- and nvl(y.MODEL_DESC,0)=nvl(o.MODEL_DESC,0) and nvl(y.STD_STYLE_DESC,0)=nvl(o.STD_STYLE_DESC,0)
- where d.ORDER_NO is not null and d.ORDER_SOURCE<>'备料需求' and d.EXE_STATUS<'3'
- ]]>
- </query>
- </queryMap>
|