| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687 |
- <?xml version="1.0" encoding="UTF-8"?>
- <queryMap desc = "设备信息管理">
- <query id = "FrmBaseCheckEquipment.doQueryEqiupment" desc = "查询设备信息">
- <![CDATA[
- SELECT T.CHECK_EQUIPMENT_NO,
- T1.DEVICE_NAME || '(' || T1.SPEC || ')' CHECK_EQUIPMENT_NAME,
- T.DEVICE_ID,
- T.DEPT_ID,
- T2.DEPARTNAME DEPT_NAME,
- T.CREATE_NAME,
- TO_CHAR(T.CREATE_TIME, 'YYYY-MM-DD HH:MM:SS') CREATE_TIME,
- T.UPDATE_NAME,
- TO_CHAR(T.UPDATE_TIME, 'YYYY-MM-DD HH:MM:SS') UPDATE_TIME,
- T.REMARK,
- T.PHY_CODE_MAX,
- T.PHY_NAME_MAX,
- T.EQUIPMENT_NAME
- FROM BASE_CHECK_EQUIPMENT T,
- RMDM_FIXEDASSETS_DETAIL T1,
- CORE_APP_DEPARTMENT T2
- WHERE T.DEVICE_ID = T1.DEVICE_ID(+)
- AND T.DEPT_ID = T2.DEPARTID(+)
- ]]>
- </query>
- <query id = "FrmBaseCheckEquipment.getEqiupmentNo" desc = "查询设备编号">
- SELECT 'E' ||
- LPAD(NVL(MAX(SUBSTR(T.CHECK_EQUIPMENT_NO, 2,4)), 0) + 1,4,0) CHECK_EQUIPMENT_NO
- FROM BASE_CHECK_EQUIPMENT T
- </query>
- <query id = "FrmBaseCheckEquipment.addEqiupment" desc = "新增设备">
- INSERT INTO BASE_CHECK_EQUIPMENT(
- CHECK_EQUIPMENT_NO,
- CHECK_EQUIPMENT_NAME,
- DEPT_ID,
- CREATE_NAME,
- CREATE_TIME,
- REMARK,
- PHY_CODE_MAX,
- PHY_NAME_MAX,
- EQUIPMENT_NAME,
- DEVICE_ID)
- VALUES(
- '#CHECK_EQUIPMENT_NO#',
- '#CHECK_EQUIPMENT_NAME#',
- '#DEPT_ID#',
- '#CREATE_NAME#',
- TO_DATE('#CREATE_TIME#','YYYY-MM-DD HH24:MI:SS'),
- '#REMARK#',
- '#PHY_CODE_MAX#',
- '#PHY_NAME_MAX#',
- '#EQUIPMENT_NAME#',
- '#DEVICE_ID#')
- </query>
- <query id = "FrmBaseCheckEquipment.updateEqiupment" desc = "修改设备">
- UPDATE BASE_CHECK_EQUIPMENT T
- SET T.CHECK_EQUIPMENT_NAME = '#CHECK_EQUIPMENT_NAME#',
- T.DEPT_ID = '#DEPT_ID#',
- T.UPDATE_NAME = '#UPDATE_NAME#',
- T.UPDATE_TIME = SYSDATE,
- T.REMARK = '#REMARK#',
- T.PHY_CODE_MAX = '#PHY_CODE_MAX#',
- T.PHY_NAME_MAX = '#PHY_NAME_MAX#',
- T.EQUIPMENT_NAME = '#EQUIPMENT_NAME#',
- T.DEVICE_ID = '#DEVICE_ID#'
- WHERE T.CHECK_EQUIPMENT_NO = '#CHECK_EQUIPMENT_NO#'
- </query>
- <query id = "FrmBaseCheckEquipment.deleteEqiupment" desc = "删除设备">
- DELETE FROM BASE_CHECK_EQUIPMENT T WHERE T.CHECK_EQUIPMENT_NO = '#CHECK_EQUIPMENT_NO#'
- </query>
- <query id="FrmBaseCheckEquipment.QueryPhyCodeMax" desc="查询各实验室的试样组">
- <![CDATA[
- select T.PHY_CODE, T.PHY_TYPE from COM_BASE_PHY_C t WHERE 1=1
- ]]>
- </query>
-
- <query id="FrmBaseCheckEquipment.initCheckEquipment" desc="试验设备">
- <![CDATA[
- select T.DEVICE_NAME || '(' || T.SPEC || ')' DEVICE_NAME, T.DEVICE_ID
- from RMDM_FIXEDASSETS_DETAIL t
- WHERE T.DEVICE_TYPE = '试验设备'
- ]]>
- </query>
-
- </queryMap>
|